An essential tool for electricians to ensure that voltage is not present before working on any electrical equipment or installation connected to the electrical system. Compliant with IEC 61243-3 Edition 2, it can be used to work on any 1000V CAT IV installation and has a redundant safety system in the event of power supply faults.
Electrical | |
Display | LEDs + backlit digital display |
Resolution | 0.1 V from 1 to 299.9 V 1 V from de 300 V |
Voltage Absence Testing (VAT) | 12 V AC ≤ U ≤ 1000 V AC; 12 V DC ≤ U ≤ 1400 V DC |
Voltage | LEDs: (12 to 1000) V AC; (12 to 1400) V DC LEDs + backlit digital display: (1 to 299 ) V AC/DC (300 to 1000) V AC / 1400 V DC |
Frequency | DC, (16.67 to 800) Hz |
Impedance | > 500 kΩ |
Maximum Peak Current | 3.5 mA RMS |
Polarity Indication | Yes |
Redundant Haxardous Voltage Indication | The ELV (Extra-Low Voltage) LED indicates that the voltage is higher than the SELV (Safety Extra-Low Voltage) with rate at flashing proportional to the voltage level |
Stray Voltage Detection | Yes (by low-impedance load switching) |
GFI Tripping | Up to 30 mA |
Phase/Neutral Identification | Above 50 V (45 to 65) Hz; above 150 V (16.67 to 45) Hz |
Response Time | <500 ms of ELV indicator: <1 s |
Intrinsic Uncertainty | ±(3% + 5 ct) |
Continuity | Continuity detection is inhibited if a voltage > 1 V is present Measurement range: 0 to 3 kΩ Intrinsic uncertainty: ±(3% + 5 ct) Resolution: 0.1Ω from 1 to 299.9Ω and 0.001 kΩ from 0.3 to 3 kΩ Audible signal triggering threshold: 100 Ω to 0% +50% Test current ≤1 mA Open circuit voltage ≤5 V |
Phase Identification | 15 Hz < frequency < 65 Hz 50 V AC < voltage < 1000 V AC for 45 Hz < frequency ≤ 65 Hz 150 V AC < voltage < 1000 V AC for frequency < 45 Hz |
Order of Phases | Phase between 45 and 400 Hz Voltage between 50 and 1000 V AC between phases Time for acquisition of information after contact ≤ 1 second Information retention time: 10 seconds Allowable unbalance amplitude: 20% Allowable voltage harmonics: 10% Rejection of EDF remote control frames (TCC-175 Hz-188 Hz) |
Lad Switching | Switched load: Approximately 8 kΩ Peak current: 90 mA Current consumed at 230 V AC: 30 mA Triggering between 8 and 400 V AC Overload protection after 10 seconds at 230 V and 2 seconds at 400 V |
General Specifications | |
Buzzer Trigger Threshold | 100 Ω typical (150 Ω maximum) |
Extended Continuity Test (Resistance) | 0.5 Ω to 2999 kΩ |
Test Current/Open-Circuit Voltage | ≤1 mA/≤3.3 V |
Phase Rotation | Two-wire method with microprocessor |
Ph/Ph Voltage | 50 V ≤ U ≤ 1000 V AC (45 to 400) Hz |
Buzzer | Intermittent beep for voltage detection continuous beep for continuity |
Altitude | < 6561.68' (< 2000 m) |
Temperature | Operating: 5 to 113°F (-15 to 45°C), Class N Storage: -40 to 158°F (-40 to 70°C) |
Power Supply | 2 x AA batteries (included) or NiMH batteries Battery life provides 2500 ten-second measurements The batteries can be replaced with rechargeable accumulators, but these will not last as long |
Electrical Safety | IEC 61243-3, EN 61243-3, IEC 61010 1000 V CAT IV |
Protection Rating | IP 65 according to IEC 60529 IK 06 - 1J - Eha pendulum hammer method according to IEC 50102 |
Degree of Pollution | 2 |
Drop Test | 6.56' (2 m) |
Dimensions | 7.72 x 3.54 x 1.85" (196 x 90 x 47 mm) |
Weight | 1.25 lbs (567 g) |