HS33 Expandable Manual Ranging Stick Multimeter for HVAC/R measures Continuity, Capacitance, AC/DC Volts, Diode Test, Resistance, and Temperature. This multimeter is equipped with a magnetic hanger to allow for hands-free to get the job done more effectively. It also features Non-contact voltage and Auto power off to conserve battery life.
Diode Test | |
Test current | ~1.0mA |
Accuracy | ±(1.5% rdg + 3 dgts) |
Open circuit volts | 3.0V DC typical |
Overload protection | 500V DC or AC rms |
Continuity | |
Audible indication | Less than 100Ω |
Response time | 100ms (Green LED will be on continuously) |
Overload protection | 500V DC or AC rms |
Capacitance | |
Range | 200μF |
Resolution | 0.1μF |
Accuracy | ±(3% rdg + 5 dgts) |
Overload protection | 500V DC or AC rms |
DC Volts | |
Ranges | 200mV, 200V, 600V |
Resolution | 0.1mV |
Accuracy | ±(0.5% rdg + 1 dgt) |
Input impedance | 560kΩ on V inputs, 10MΩ on mV input |
Overload protection | 600V DC or AC rms, 500V DC/350V AC rms 15 sec on 200mV range |
Transient protection | 6kV for 10μ sec |
AC Volts (50Hz to 500Hz) |
|
Ranges | 200mV, 200V, 600V |
Resolution | 0.1mV |
Accuracy | ±(1.2% rdg + 3 dgts) ±(2.0% rdg + 5 dgts) on 600V range |
Input impedance | 560kΩ on V input, 10MΩ on mV input |
Overload protection | 600V DC or AC rms |
Transient protection | 6kV for 10μ sec |
Resistance | |
Ranges | 200Ω to 200kΩ |
Resolution | 0.1Ω |
Accuracy | ±(1.0% rdg + 4 dgts) |
Open circuit volts | 0.3V DC typical, (3.0V DC on 200Ω range) |
Overload protection | 500V DC or AC rms |
Temperature | |
Range | -30 to 200°F (-34 to 93°C) |
Resolution | 0.1°F/°C |
Accuracy | ±1°F, 32 to 120°F (0 to 48°C), ±1% + 1.5°F, -4 to 200°F (-20 to 93°C), ±2% + 3°F, -30 to -4°F (-34 to -20°C) |
Sensor type | K-type thermocouple |
Overload protection | 60 V DC or 30 V AC rms |
General Specifications | |
Display | 3-1/2 digit liquid crystal display (LCD) with a maximum reading of 1999 |
Overrange | "OL" mark indication |
Auto power off | 60 minutes |
Operating enviroment | 32 to 122°F (0 to 50°C) at <70% R.H. |
Storage temperature | -4 to 140°F (-20 to 60°C), 0 to 80% R.H. with battery removed |
Accuracy | Specifications good in ambient conditions of 73°F W9°F (23°C W5°C), <75% relative humidity |
Temperature Coefficient | 0.1x(specified accuracy) per °F/°C. (32 to 64°F (0 to 18°C), 82 to 122°F (28 to 50°C)) |
Power | Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22 |
Battery life | 300 hours typical with alkaline |
Accessories | One pair test leads, one pair alligator clips, k-type thermocouple (HS33), 9V battery (installed), and operating instructions |
Safety | UL, CE, Cat III 600V, UL3111, IEC/EN61010-1, C-Tick certified |