HS36 Expandable True RMS HVAC/R Multimeter with backlight takes readings for Continuity, Capacitance, Alternating Current/Direct Current Volts, Direct Current, Frequency, Resistance, and Temperature. This multimeter has a bright backlit LCD screen and magnetic holster for hands-free operation. It has Non-contact voltage capabilities as well as an Auto-off function and is packed with the features HVAC/R technicians need.
Frequency | |
Ranges | 4k, 40k, 400k, 4M, 40MHz |
Resolution | 1Hz |
Accuracy | ±(0.1% rdg + 3 dgts) |
Sensitivity | 10Hz ~ 4MHz: > 1Vrms 4MHz ~ 40MHz: > 2Vrms, <5Vrms |
Minimum pulse width | > 25ns |
Duty cycle limits | > 30% and < 70% |
Overload protection | 500V DC or AC rms |
Continuity | |
Audible indication | Less than 40Ω |
Response time | 500ms (Green LED will be on continuously) |
Overload protection | 500V DC or AC rms |
Capacitance | |
Range | 400μF |
Resolution | 0.1μF |
Accuracy | ±(3% rdg + 5 dgts) |
Overload protection | 500V DC or AC rms |
DC Volts | |
Ranges | 400mV, 4000mV, 40V, 400V, 600V |
Resolution | 0.1mV |
Accuracy | ±(0.5% rdg + 2 dgt) |
Input impedance | 3MΩ on V inputs, 10MΩ on mV input |
Overload protection | 600V DC or AC rms |
Transient protection | 6kV for 10μ sec |
AC Volts (50Hz to 500Hz) |
|
Ranges | 400mV, 4V, 40V, 400V, 600V |
Conversion | True RMS |
Resolution | 0.1mV |
Accuracy | ±(1.2% rdg + 5 dgts) 50Hz ~ 60Hz on 400mV range ±1.5% rdg + 5 dgts) ±(2% rdg + 5 dgts) on 600V range |
Input impedance | 3MΩ |
Overload protection | 600V DC or AC rms |
Transient protection | 6kV for 10μ sec |
Resistance | |
Ranges | 400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ, 40MΩ |
Resolution | 0.1Ω |
Accuracy | ±(1.0% rdg + 4 dgts) on 400Ω to 400kΩ ranges ±(1.5% rdg + 4 dgts) on 4MΩ range ±(3.0% rdg + 5 dgts) on 40MΩ range |
Open circuit volts | -0.45 V DC typical, (-1.2 V DC on 400Ω range) |
Overload protection | 500 V DC or AC rms |
Temperature | |
Range | -30 to 1000°F (-34 to 538°C) |
Resolution | 0.1°F/°C |
Accuracy | ±1°F, 32 to 120°F (0 to 49°C) ±1% + 1.5°F, -4 to 750°F (-20 to 399°C) ±2% + 4°F, -30 to -4°F (-34 to -20°C) ±2% + 4°F, 750 to 1000°F (399 to 538°C) |
Sensor type | K-type thermocouple |
Overload protection | 60 V DC or 30 V AC rms |
DC current | |
Ranges | 400μA, 4000μA |
Resolution | 0.1μA |
Accuracy | ±(1.0% rdg + 2 dgt) |
Voltage burden | 1V, (8V on 4000μA range) |
Overload protection | 500V DC or AC rms |
General Specifications | |
Display | 3-3/4 digit liquid crystal display (LCD) with a maximum reading of 3999 |
Analog bar graph | 41 segments with measurements 20 times per second |
Overrange | "OL" mark indication |
Auto power off | 30 minutes |
Operating enviroment | 32 to 122°F (0 to 50°C) at <70% R.H. |
Storage temperature | -4 to 140°F (-20 to 60°C), 0 to 80% R.H. with battery removed |
Accuracy | Specifications good in ambient conditions of 73°F ±9°F (23°C ±5°C), <75% relative humidity |
Temperature Coefficient | 0.1x(specified accuracy) per °F/°C. 32 to 64°F (0 to 18°C) 82 to 122°F (28 to 50°C) |
Power | Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22 |
Battery life | 300 hours typical with alkaline |
Accessories | One pair test leads, one pair alligator clips, k-type thermocouple, 9V battery (installed), and operating instructions |
Safety | UL, CE, Cat III 600V, UL61010-1, IEC/EN61010-1 |
Pemberitahuan : Harga dapat berubah sewaktu-waktu (mengikuti perubahan kurs dolar)
Ketersediaan : 4-6 minggu