LT17A Digital Multimeter can measure Temperature as well as Alternating Current/Direct Current Voltage and Current, Frequency, Capacitance, Resistance, Temperature, and Diode Testing. Changeable test leads means you can change the heads and the ABS plastic case is extremely durable. This meter has a bright backlight and a K-type thermocouple.
DC Voltage | |
Ranges | 200mV, 2000mV, 20V, 200V, 600V |
Resolution | 0.1mV |
Accuracy | 0.5%±1 |
Input Impedence | 10MΩ |
AC Voltage (50Hz-500Hz) |
|
Ranges | 200mV, 2000mV, 20V, 200V, 600V |
Resolution | 0.1mV |
Accuracy | 1.2% ±4: 200mV to 20V ranges 2% ±4: 200V and 600V ranges |
Input Impedence | 10MΩ |
DC Current (through meter) |
|
Ranges | 200μA, 20mA, 200mA |
Resolution | 0.1μA |
Accuracy | 1.0%±1 |
Voltage burden | 800mV |
AC Current (through meter) |
|
Ranges | 200μA, 20mA, 200mA |
Resoltuion | 0.1μA |
Accuracy | 1.5%±4 |
Voltage burden | 800mV |
Frequency (autoranging) |
|
Range | 10Hz to 40KHz |
Resoltuion | 1Hz |
Sensitivity | 3.5V rms min |
Accuracy | 0.1% ±3 |
Resistance (ohms) |
|
Ranges | 200Ω, 2kΩ, 200kΩ, 20MΩ |
Resolution | 0.1Ω |
Accuracy | 1.0%±4 (200Ω to 200kΩ ranges) 2.0%±4 (20MΩ range) |
Open circuit voltage | 0.3V DC typical, (3.0V DC on 200Ω) |
Diode Test | |
Accuracy | 1.5%±3 |
Test current | 1.0mA approx. |
Open circuit voltage | 3.0V DC typical |
Capacitance (MFD) |
|
Ranges | 200μF, 2kμF, 20kμF |
Resolution | 0.1μF |
Accuracy | 4% ±10 |
Test frequency | 21Hz |
Test voltage | <3.0V |
Temperature | |
Ranges | -30 to 1400°F (-34 to 750°C) |
Resolution | 0.1°F/°C |
Accuracy | ±1°F; 32 to 120°F (±0.5°C; 0 to 48°C) ±1.0%+1.5°F; -4 to 750°F (±1.0%+1.0°C; -20 to 399°C) ±3.0%+4°F; -30 to -4°F and 750 to 1400°F (±3.0%+2°C; -34 to -20°C and 399 to 750°C) |
Sensor type | K-type thermocouple |
Others | |
Field Calibration (temp offset pot) |
The LT17A can be easily calibrated on the job. Use a bucket of ice water to have a known 32°F (0°C) temperature. With the thermocouple in the ice water, adjust the TEMP OFFSET pot on the face of the meter until it reads 32.0 (0.0) |
Fuse Replacement | When only certain ranges quit working, check the fuse. Open the case and replace according tothe Overload Protection values below. If that doesn't work visit our Warranty Page.to check for other problems. |
Overload Protection |
|
V AC/DC | (200mV range ) 600VAC/DC rms for 15 sec (>200mV range) 600VAC/DC rms |
A AC/DC | 0.25A/500V fuse (6.3X32mm) |
Capacitance | 0.25A/500V fuse (6.3X32mm) model RFM66 |
Temperature | 30V AC/DC rms |
Frequency | 500V AC/DC rms |
Resistance | 500V AC/DC rms |
Diode Test | 500V AC/DC rms |
Continuity | 500V AC/DC rms |
General Specifications | |
Auto-off | off after 25 minutes to extend battery |
Indicators | Continuity beeper (<100Ω). Low bat |
Overrange | "OL" or "OL" is displayed |
Operating environment | 32 to 122°F (0 to 50°C) <70%RH |
Storage environment (with batteries removed) |
-4 to 140°F (-20 to 60°C) <80%RH |
Altitude | 6561.7 feet (2000m) |
Battery life | 150 hours typical |
Battery type | 9V NEDA 1604 type |
Stated accuracies | 74°F ±8°F (23°C ±4°C), 75%RH |
Temperature coefficient | 0.1 x (specified accuracy) 1°F/°C (32 to 66°F (0 to 19°C), 82 to 122°F (28 to 50°C)) |
What's Included? | Classic Style Clamp Meter with Temperature (LT17A), Deluxe Silicone Test Leads (ADLS2), 400A Amp Clamp Accessory (ACH4), Wrap Tab Bead Tip Thermocouple (ATB1), Short Alligator Lead Extensions (ASA2), Mail Pouch-Style Instrument Case (ANC5), 9-Volt battery (installed), OperatorÆs manual |
Pemberitahuan : Harga dapat berubah sewaktu-waktu (mengikuti perubahan kurs dolar)
Ketersediaan : 4-6 minggu